2-wire Digital Meter (Loop Powered) 6DV/6DV-B

back

2-wire Digital Meter (Loop Powered) 6DV/6DV-B

4-digit, Input Loop Powered

  • 70 mm dia., D 21 mm (6DV, 6DVI)
  • W 110 x H 118 x D 92 mm (6DV-B, 6DVI-B)
  • 4-digit red LED (-1999 to 9999)
  • 4-20 mA input powered
  • No external power source required
  • Scaling & linearization selectable via the front control buttons
  • Mountable on top of head-mount transmitter, installed together in an outdoor encloure (6DV, 6DVI)
  • NEMA 4X, IP66 / IP67 (6DV-B, 6DVI-B)
CE ATEX FM Explosion-proof IP66/IP67

Depending on the model.

Number of Display Digits 4 Digits Intrinsic Safety Explosion-proof Loop Powered
  • Intrinsically safe approvals are available from ATEX Directive (Europe) and FM (US, Canada). Differences between the 6DV and the 6DVI exist only in safety parameters (See Table).

    A safety barrier with matching safety parameters to the 6DV or 6DVI must be installed for complete intrinsic safety. The safety barrier should meet the Ex-data of this unit and must be approved for hazardous location.

    Table

    Operating Temperature
      Temp Class Operating Temperature
    6DV 6DVI
    FM/ATEX T4 Intrinsically safe T4 -40 to +80°C -40 to +85°C
    T5 -40 to +60°C -40 to +60°C
    Intrinsic Safety Ex Data
      6DV 6DVI
    Ui (Vmax) 30V DC 28V DC
    Ii (Imax) 100mA DC 120mA DC*1
    Pi (Pmax) 0.75W 0.84W
    Ci 1.0 nF 1.0 nF
    Li 0 mH 0 mH

    *1. Max. current allowed for the safety approval; Not to guarantee the product’s performance.