Signal Conditioners
Converting measured signals to desired signals.
Signal conditioners convert a field signal from various sensors into standard signal suitable for processing in PLC, DCS or PC-based systems. They are also used to boost a signal to increase load drive capability, to isolate a signal to stop ground loops.
More than 75000 combinations of process signal I/O, power input and mounting configuration are selectable. Additionally, we offer the broadest line of signal splitters available.
Low Profile
Compact Plug-in
-
Space-saving Plug-in
F-UNIT Series -
Space-saving Plug-in
H-UNIT Series
Ultra-Slim
-
Base-free Interconnecting Ultra-Slim
M60 Series- CE
-
Ultra-Slim
M6 Series- CE
- UL
Super-mini
-
Dual Output
10-RACK Series -
DCS Front End
18-RACK Series -
Interposing Relays
38-RACK Series
Isolation Amplifiers
-
Hybrid IC Isolation Amplifiers
20 Series- CE
Plug-in
Matrix Table
Quick Comparison Chart - Main Products
Terminal Block Signal Conditioners with Display M50E-UNIT Series |
Low Profile M50X-UNIT Series |
Low Profile M5-UNIT Series |
Low Profile Signal Splitters W5-UNIT Series |
|
---|---|---|---|---|
Construction | Terminal block | Terminal block | Terminal block | Terminal block |
Connection | Tension clamp terminal | Tension clamp terminal | M3.5 screw terminal | Input: M3.5 screw terminal Output & power: M3 screw terminal |
Isolation | Five ways | Five ways | Three ways | Four ways |
Dielectric Strength |
2000 V AC (current input or voltage input to Modbus to pulse output 1 or pulse output 2 to power) |
2000 V AC | DC powered:2000 V AC AC powered:1500 V AC |
2000 V AC (input to output 1 or output 2 to power to ground) |
Fixed Range | Specified when ordering | Specified when ordering | Specified when ordering | Specified when ordering |
Range Selectability |
PC | PC | PC | DIP switch |
Dual Output | — | — | — | Yes |
2 channel | — | — | — | — |
Power Input | AC / DC (universal) | AC / DC (universal) | AC / DC | AC / DC |
Operating Temperature |
-20 to +65°C (-4 to 149°F) |
-20 to +65°C (-4 to 149°F) |
-5 to +55°C (23 to 131°F) |
-5 to +55°C (23 to 131°F) |
Mounting | DIN rail | DIN rail | DIN rail | DIN rail |
Size mm (inch) |
W 22.5 (.89) | W 28 (1.10) | W 25 (.98) | W 45 (1.77) |
H 115 (4.53) | H 105 (4.13) | H 97 (3.82) | H 97 (3.82) | |
D 55 (2.17) | D 41 (1.61) | D 41 (1.61) | D 41 (1.61) | |
Standards & Approvals |
CE | CE | CE | CE |
Isolators & Sensor Inputs |
Yes | Yes | Yes | Yes |
Power Transducers | Yes | Yes | Yes | — |
Frequency I/O | Yes | Yes | Yes | Yes |
Pneumatic Transducers |
— | — | — | — |
Limit Alarms | — | — | — | — |
A/D & D/A Transducers |
— | — | — | — |
Function Module & Math Function Module |
— | — | Yes | — |
Valve Positioners | — | — | — | — |
Manual Loading Station | — | — | — | — |
Others | — | — | — | — |
Base-free Interconnecting Ultra-Slim M60 Series |
Ultra-Slim M6 Series |
Thin Profile M3-UNIT Series |
Thin Profile M3S-UNIT Series |
|
---|---|---|---|---|
Construction | Ultra-slim | Ultra-slim | Front terminal access | Front terminal access |
Connection | Spring clamp terminal, e-CON connector |
Tension-clamp, M3 screw terminal, Euro rminatel |
Removable terminal block | Removable terminal block |
Isolation | Three / Four ways | Three / Four ways | Three ways | Three ways |
Dielectric Strength |
1500 V AC | 2000 V AC | DC powered:2000 V AC AC powered:1500 V AC |
2000 V AC |
Fixed Range | Specified when ordering | Specified when ordering | — | Specified when ordering |
Range Selectability |
DIP switch | PC | One-Step Cal, PC | PC |
Dual Output | Yes | — | — | △ |
2 channel | — | — | — | — |
Power Input | DC | AC / DC | AC / DC | AC / DC (universal) |
Operating Temperature |
-20 to +55°C (32 to 131°F) |
-20 to +55°C (32 to 131°F) |
-25 to +65°C (-13 to +149°F) , -25 to +55°C (-13 to +131°F) (for UL approval) |
-10 to +55°C (32 to +131°F) |
Mounting | DIN rail | DIN rail, Multi-channnel Installation Base (Surface) | DIN rail | DIN rail |
Size mm (inch) |
W 8 (.31) | W 5.9 (.23), 7.5 (.30) | W 18 (.71) | W 12 (.47) |
H 108 (4.25) | H 94 (3.70), 102 (4.02) | H 106 (4.17) | H 106 (4.17) | |
D 102 (4.02) | D 102 (4.02) | D 110.5 (4.35) | D 110.5 (4.35) | |
Standards & Approvals |
CE | CE / UL / C-UL | CE / UL / C-UL | CE |
Isolators & Sensor Inputs |
Yes | Yes | Yes | Yes |
Power Transducers | — | Yes | — | — |
Frequency I/O | — | Yes | Yes | — |
Pneumatic Transducers |
— | — | — | — |
Limit Alarms | — | Yes | — | — |
A/D & D/A Transducers |
— | — | — | — |
Function Module & Math Function Module |
— | Yes | — | — |
Valve Positioners | — | — | — | — |
Manual Loading Station | — | — | — | — |
Others | — | — | — | — |
Compact Plug-in M1E Series with OEL display |
Compact Plug-in Mini-M Series |
Compact Plug-in Mini-M Series with OEL display |
Compact Plug-in Signal Splitters Mini-MW Series |
Plug-in K-UNIT Series |
|
---|---|---|---|---|---|
Exterior | |||||
Construction | Plug-in | Plug-in | Plug-in | Plug-in | Plug-in |
Connection | M2.6 screw terminal | M3 screw terminal | M3 screw terminal | M3 screw terminal | M3.5 screw terminal |
Isolation | Five / Nine ways | Three ways | Three ways | Four ways | Three / Four ways |
Dielectric Strength |
1500 V AC | 2000 V AC | 2000 V AC | 2000 V AC | 2000 V AC |
Fixed Range | — | Specified when ordering | — | Specified when ordering | Specified when ordering |
Range Selectability |
Program with front buttons or PC programming |
Specified when ordering or PC / One-Step Cal programming |
Program with front buttons or PC programming |
Specified when ordering or PC programming |
— |
Dual Output | Selected models (Multi-output model) |
Selected models | — | Yes | Selected models |
2 or 4-channel | Selected models (4 channels) |
— | — | — | — |
Power Input | AC / DC | AC / DC | AC / DC | AC / DC | AC / DC |
Operating Temperature |
-5 to +55°C (23 to 131°F) |
-5 to +55°C (23 to 131°F) , -20 to +80 °C (-4 to +176°F); (M2VT,M2TT,M2RT) |
-5 to +55°C (23 to 131°F) |
-5 to +55°C (23 to 131°F) |
-5 to +55°C (23 to 131°F) |
Mounting | Surface or DIN rail | Surface or DIN rail | Surface or DIN rail | Surface or DIN rail | Surface or DIN rail |
Size mm (inch) |
W 36 (1.42) | W 23 (.91), 29.5 (1.16) |
W 29.5 (1.16) | W 29.5 (1.16) | W 50 (1.97) |
H 99 (3.90)*1 | H 76 (2.99) | H 83 (3.27) | H 88.5 (3.49) | H 80 (3.15) | |
D 125 (4.92)*1 | D 124 (4.88) | D 124 (4.88) | D 124 (4.88) | D 123 (4.84), 132 (5.20) (except for some models) |
|
Standards & Approvals |
CE | CE / UKCA / UL / C-UL | CE | CE / UKCA / UL / C-UL | CE |
Isolators & Sensor Inputs |
Yes | Yes | Yes | Yes | Yes |
Power Transducers | — | Yes | — | Yes | Yes |
Frequency I/O | — | Yes | — | Yes | Yes |
Pneumatic Transducers |
— | Yes | — | Yes | — |
Limit Alarms | Yes | Yes | Yes | — | Yes |
A/D & D/A Transducers |
— | — | — | — | Yes |
Function Module & Math Function Module |
— | Yes | — | Yes | Yes |
Valve Positioners | — | — | — | — | Yes |
Manual Loading Station | — | — | — | — | — |
Others | — | Yes | — | — | — |
*1. With the base (Model: M1E-BS2) installed
Plug-in Front Configurable MX-UNIT Series |
Plug-in M-UNIT Series |
Plug-in Signal Splitters W-UNIT Series |
Space-saving Plug-in F-UNIT Series |
Space-saving Plug-in H-UNIT Series |
|
---|---|---|---|---|---|
Exterior | |||||
Construction | Plug-in | Plug-in | Plug-in | Plug-in | Plug-in |
Connection | M3.5 screw terminal | M3.5 screw terminal | M3.5 screw terminal | M3.5 screw terminal | M3.5 screw terminal |
Isolation | Three ways | Three ways | Four ways | Three ways | Three ways |
Dielectric Strength |
2000 V AC | 2000 V AC | 2000 V AC (input to output 1 or output 2 to power to ground) |
1000 V AC (input to output) |
500 V AC (input to output to power) |
Fixed Range | — | Specified when ordering | Specified when ordering | Specified when ordering | Specified when ordering |
Range Selectability |
Display + Front key | PC, Programming unit | PC, Programming unit | PC, Programming unit | PC, Programming unit |
Dual Output | — | — | Yes | — | — |
2 channel | — | — | — | — | — |
Power Input | AC / DC | AC / DC | AC / DC | AC / DC | DC |
Operating Temperature |
-5 to +55°C (23 to 131°F) |
-5 to +60°C (23 to 140°F) |
-5 to +55°C (23 to 131°F) |
-5 to +55°C (23 to 131°F) |
-5 to +55°C (23 to 131°F) |
Mounting | Surface or DIN rail | Surface or DIN rail | Surface or DIN rail | Surface or DIN rail | Surface or DIN rail |
Size mm (inch) |
W 50 (1.97) | W 50 (1.97) | W 50 (1.97) | W 26 (1.02) | W 26 (1.02) |
H 80 (3.15) | H 80 (3.15) | H 80 (3.15) | H 100 (3.94) | H 93 (3.66) | |
D 123 (4.84), 132 (5.20) | D 127 (5), 136 (5.35) (except for some models) |
D 136 (5.35) | D 137 (5.39) | D 137 (5.39) | |
Standards & Approvals |
CE | CE / UL | CE | — | — |
Isolators & Sensor Inputs |
Yes | Yes | Yes | Yes | Yes |
Power Transducers | — | Yes | Yes | — | — |
Frequency I/O | Yes | Yes | Yes | Yes | Yes |
Pneumatic Transducers |
— | Yes | — | — | Yes |
Limit Alarms | — | Yes | — | Yes | Yes |
A/D & D/A Transducers |
— | Yes | — | — | — |
Function Module & Math Function Module |
Yes | Yes | Yes | Yes | Yes |
Valve Positioners | — | Yes | — | — | — |
Manual Loading Station | Yes | Yes | — | — | — |
Others | — | Yes | — | — | Yes |
Dual Output Super-mini Signal Conditioners Pico-M Series |
Super-mini Signal Conditioners M80 Series |
Dual Output 10-RACK Series |
DCS Front End 18-RACK Series |
|
---|---|---|---|---|
Construction | Plug-in to multi-channnel installation base | Plug-in to dedicated 8 base | Rack-mounted; terminal access via screw terminals at the front and via card-edge connector at the rear; terminal cover provided | Rack-mounted; terminal access via screw terminals on the front and connector on the rear; terminal cover provided |
Connection | M3.5 screw terminal, DCS connector of each company (at base) | M3.5 screw terminal, Connector (at base) | Input: M3.5 screw terminals (torque 0.8 N·m) | Input: M3.5 screw terminals (torque 0.8 N·m) |
Output: Card-edge connector and M3.5 screw terminals (torque 0.8 N·m) | Output 1 & 2: Connector Monitor output: M3.5 screw terminals (torque 0.8 N·m) Power input: Supplied from connector |
|||
Isolation | Four ways | Three ways | Four ways | Four ways |
Dielectric Strength |
1500 V AC (input to output 1 to output 2 to power to ground) |
1000 V AC | 500 V AC (output 1 to output 2 to power) |
1500 V AC (input or output or power to ground) |
Fixed Range | Specified when ordering | Specified when ordering | Specified when ordering | Specified when ordering |
Range Selectability |
PC | — | PC, Programming unit | PC, Programming unit |
Dual Output | Yes | — | Yes | Yes |
2 channel | — | — | — | — |
Power Input | AC / DC | DC | AC / DC | AC / DC |
Operating Temperature |
0 to 55°C (32 to 131°F) |
-5 to +55°C (23 to 131°F) |
-5 to +55°C (23 to 131°F) |
-5 to +55°C (23 to 131°F) |
Mounting | Multi-channnel Installation Base (Surface) | Dedicated base (DIN rail, Surface) |
Standard Rack 10BXx | Standard Rack 18BXx or 18KBXx |
Size mm (inch) |
W 17.5 (.69) | W 14 (.55) | W 25 (.98) | W 24 (.94) |
H 48 (1.89) | H 39.2 (1.54) | H 99 (3.90) | H 110 (4.33) | |
D 75 (2.95) | D 50.5 (1.99) | D 181 (7.13) | D 110 (4.33) | |
Standards & Approvals |
CE | CE | — | — |
Isolators & Sensor Inputs |
Yes | Yes | Yes | Yes |
Power Transducers | Yes | — | Yes | Yes |
Frequency I/O | Yes | — | Yes | Yes |
Pneumatic Transducers |
— | — | Yes | Yes |
Limit Alarms | Yes | — | Yes | Yes |
Function Module & Math Function Module |
Yes | — | Yes | Yes |
Manual Loading Station | — | — | Yes | — |
Others | — | — | Yes | Yes |