Pulse & ON/OFF Signal

Pulse & ON/OFF Signal

  • Lightning Surge Protector for Pulse Signal (ultra-slim)
    MD7PL CEATEX
    Model: MD7PL
    • Ultra-thin 7-mm-wide module can be mounted in high density
    • Excellent protection employing multi-stage SPD circuits
    • DIN rail mounting and grounding
    • Shield terminal provided
    • Protects two pulse signal lines
    • Maximum continuous operating voltage (Uc):
      Positive common: -30 V
      Negative common: +30 V
    • Voltage protection level (Up):
      Positive common: -50 V
      Negative common: +50 V
    • Max. discharge current (Imax) or discharge current capacity: 20 kA (8/20 μs), 1.0 kA (10/350 μs)
  • Lightning Surge Protector for Low Frequency Use
    MDP-SP CE
    Model: MDP-SP
    • Designed specifically to protect frequency generating devices such like flowmeters and frequency transmitters from lightning surge damage that enters on the wiring between these instruments
    • Absorbs surges only without affecting instrumentation signal
    • No interruption of signal by unplugging the protector element
    • Maximum continuous operating voltage (Uc): ±14 V (B to C), 14 V (B or C to A)
    • Voltage protection level (Up): ±30 V (2 to 3), 30 V (2 or 3 to 1)
    • Max. discharge current (Imax) or discharge current capacity: 5000 A (8/20 μs)
  • Lightning Surge Protector for Multi-Channel Use (high discharge current capacity)
    MDR2 CE
    Model: MDR2
    • Protection for semiconductor switches of discrete outputs against lightning surge damage
    • Applicable to both negative and positive common signals
    • Applicable to multi analog signals (non-isolation between channels)
    • Space saving with multi-channel protectors
    • LED monitor indicating degradation of voltage limiter
    • LED monitor driven by discrete I/O signal without auxiliary power supply
    • Maximum continuous operating voltage (Uc):
      Positive common: -30 V
      Negative common: +30 V
    • Voltage protection level (Up) @ 4 kV / 2 kA (1.2/50 μs):
      Without leakage current indicator: -50 V (Positive common), +50 V (Negative common)
      With leakage current indicator: -60 V (Positive common), +60 V (Negative common)
    • Maximum discharge current (Imax): 10 kA
  • Multi M-RESTER
    MDR-8
    Model: MDR-8
    • Designed specifically for ON-OFF signals, protecting semiconductor switches used for ON-OFF outputs from the computer or PLC from lightning surge damage that enters on the wiring between these instruments
    • 8 channels
    • Most convenient as junction board
    • Minimum mounting space
    • Maximum continuous operating voltage (Uc): 30 V
    • Voltage protection level (Up): 40 V
    • Max. discharge current (Imax) or discharge current capacity: 1000 A (8/20 μs)