Power Supply Line, Medium/Large Capacity

Medium/Large Capacity Power Supply Line

  • Lightning Surge Protector for Power Supply Use (20 A)
    MAH
    Model: MAH
    • Designed specifically for power requirements of medium capacities (20 amps)
    • Protecting electronic equipment from lightning surges that enter through power supply circuits
    • Surge absorber failure indicated with LED
    • Detaching the discharge elements from the power supply circuits when fuses are blown
    • Single phase 2-wire, 100/110/120 V AC (MAH-121)
    • Single phase 2-wire, 200/220/240 V AC (MAH-221)
    • Single phase 3-wire, 100/110/120 V AC (MAH-123)
    • Three phase 3-wire, 200/220/240 V AC (MAH-223)
    • Maximum continuous operating voltage (Uc):
      190 V (MAH-121)
      380 V (MAH-221, MAH-223)
      190 V line to neutral, 380 V line-to-line (MAH-123)
    • Voltage protection level (Up):
      350 V (MAH-121)
      700 V (MAH-221, MAH-223)
      350 V line to neutral, 700 V line-to-line (MAH-123)
    • Discharge current capacity 10000 A (8/20 μs)
  • Lightning Surge Protector for Power Supply Use (10-30 A replaceable arrester module)
    MMH
    Model: MMH
    • Designed specifically for power requirements of medium capacities (10 or 30 A)
    • Separating the arrester module when a leak current is detected at the module
    • Relay contact and front LED turn ON in case of the arrester module failure
    • The plugin type arrester module can be easily replaced
    • 100/110 V AC (MMH-110, MMH-130)
    • 200/220 V AC (MMH-210, MMH-230)
    • Maximum continuous operating voltage (Uc):
      190 V (MMH-110, MMH-130)
      410 V (MMH-210, MMH-230)
    • Voltage protection level (Up):
      350 V (MMH-110, MMH-130)
      700 V (MMH-210, MMH-230)
    • Maximum load current:
      10 A (MMH-110, MMH-210)
      30 A (MMH-130, MMH-230)
    • Discharge current capacity 10000 A (8/20 μs)
  • Arrester Module (For MMH use)
    Model: MEH
    • MMH Dedicated Lightning Surge Protection Module
    • With disconnection function at detection of leakage current due to surge absorber element error
    • With error alarm contact output and error display monitor LED
    • Plug-in type with easy replacement
  • Lightning Surge Protector for Power Supply Use (5-30 A)
    MH-105A/MH-110A/MH-130A
    Model: MH-105A
    Model: MH-110A
    Model: MH-130A
    • Designed specifically for power requirements of medium capacities
    • Protecting electronic equipment from lightning surges that enter through substations and step-down transformers
    • Discharge element failure triggers the fuse blown and alarm contact closed
    • Also effective in rejecting switching transients generated by thyristors, circuit breakers, motor starters, etc.
    • 100/110/120 V AC
    • Maximum continuous operating voltage (Uc): 190 V
    • Voltage protection level (Up): 350 V
    • Maximum load current: 5 A (MH-105A), 10 A (MH-110A), 30 A (MH-130A)
    • Discharge current capacity 10000 A (8/20 μs)
  • Lightning Surge Protector for Power Supply Use (5-30 A)
    MH-205A/MH-210A/MH-230A
    Model: MH-205A
    Model: MH-210A
    Model: MH-230A
    • Designed specifically for power requirements of medium capacities
    • Protecting electronic equipment from lightning surges that enter through substations and step-down transformers
    • Discharge element failure triggers the fuse blown and alarm contact closed
    • Also effective in rejecting switching transients generated by thyristors, circuit breakers, motor starters, etc.
    • 200/220/240 V AC
    • Maximum continuous operating voltage (Uc): 410 V
    • Voltage protection level (Up): 700 V
    • Maximum load current: 5 A (MH-205A), 10 A (MH-210A), 30 A (MH-230A)
    • Discharge current capacity 10000 A (8/20 μs)
  • Lightning Surge Protector for Power Supply Use (200 A)
    MH-1201/MH-2201/MH-2203
    Model: MH-1201
    Model: MH-2201
    Model: MH-2203
    • Designed for installation where AC power enters the control panel for relatively large power consuming equipment such as large instrumentation panels, computer systems or telemetering systems in central control rooms or operation centers
    • Composed of air-core reactors, large capacity discharge elements and electromagnetic contactors
    • Thermal fuse in parallel with the discharge element opens and cuts off the operating circuit for the electromagnetic contactor in case of discharge elements failure, thus protecting the equipment connected to the arrester
    • Single phase, 100/110/120 V AC (MH-1201)
    • Single phase, 200/220/240 V AC (MH-2201)
    • 3-phase, 200/220/240 V AC (MH-2203)
    • Maximum continuous operating voltage (Uc): 190 V (MH-1201), 380 V (MH-2201, MH-2203)
    • Voltage protection level (Up): 350 V (MH-1201), 700 V (MH-2201, MH-2203)
    • Discharge current capacity 10000 A (8/20 μs)