Unique & Special
Unique & Special
-
50 mA Output
- Specific input within ±300 V; current input with a resistor
- Non-isolated 10-50 mAdc output
- 100, 110, 120, 200, 220, 240 V AC powered
VA Data Sheet Applications: Interfacing between 10-50 mA and 4-20 mA systems
-
200 mA Output
- Specific input within ±300 V; current input with a resistor
- Isolated 10-50 mA, 0-50 mA, 0-100 mA, 0-200 mA, 0-20 V DC output
- 100-120 V, 200-240 V AC or 110 V DC powered
SVA CE Data Sheet Applications
: Retrofitting 10-50 mAdc control system; DC excitation for an electromagnetic coil which demanss a high power; Driving actuators used in turbines, speed governors, and vari-axial fan control actuators; Valve positioners/actuators utilized in hydraulic equipment requiring 0-200 mAdc signal conversion from a standard DC signal level
-
1 A Output
- Specific input within ±300 V; current input with an internal resistor
- Isolated 0-1 Adc output
- 85-264 V AC powered
- 50% zero & span adjustments
- Low heat emission design (12W with maximum load)
99SVA Data Sheet Applications: Driving hydraulic machinery; Remote setting for testing equipment
-
30 V Output
- Specific input within ±300 V; current input with a resistor
- Specific output within ±20 mA or -20 to +30 V
- 1500 ohm load resistance at 20 mA output
- 100-240 V AC or 24 V DC powered
- Fast response 25 msec. optional
- 0-100 % output LCD display optional
SVB CE Data Sheet
-
RTD Output
- Emulates the RTD resistance proportional to a DC signal
- 4-20 mA or 1-5 V DC input
- Pt 100 equivalent resistance output
- 100, 110, 115, 120, 200, 220, 240 V AC or 12, 24, 48 V DC powered
- Response time 0.5 seconds or less
- Output drive circuit with semiconductor switches ensures long life span
- Fixed output at power failure
CVRTD CE Data Sheet Product Features Applications: Controlling an RTD input device with a DC signal
-
Potentiometer Output
- 0-10 V, 0-1 V, 0-5 V, 1-5 V DC input; current input with a resistor
- 135, 1k, 100, 200, 500, 2k, 5k, 10k, 20k, 50k, 100k ohms output
- 100-240 V AC or 24 V DC powered
- Automatic deadband adjustment from 0.1 to 2% of span to avoid hunting
- Permissible wattage 1W
CVR1 CE Data Sheet Product Features Applications: Remote setting for inverters; Remote setting for Honeywell’s Modutrol motors; Remote setting for various instruments with potentiometer settings
-
Self-synch Input, 2-channel, PC programmable, with OEL display
- Converts position signal from a self-synchronizing motor into a DC signal proportional to the rotating shaft position
- Input range selectable within 0-359.99 degrees
- Output selectable within 0-20 mA, ±5 V, and±10 V
- 100-120 V AC powered
- Linearization
- 0 % and 100 % output range can be easily selected with the front buttons
- 2 channels
M1EXS-2 CE Data Sheet Applications: Position indicator using self-synch for valves and gates; Tank gauge; Sounding level meter
-
Self-synch Input, PC programmable, with OEL display
- Converts position signal from a self-synchronizing motor into a DC signal proportional to the rotating shaft position
- Input range selectable within 0-359.99 degrees
- Output selectable within 0-20 mA, ±5 V, and±10 V
- 100-120 V AC or 200- 240 V AC powered
- Linearization
- 0 % and 100 % output range can be easily selected with the front buttons
M2EXS CE Data Sheet Applications: Position indicator using self-synch for valves and gates; Tank gauge; Sounding level meter
-
Self-synch Input
- Converts position signal from a self-synchronizing motor into a DC signal proportional to the rotating shaft position
- Input range selectable within 0-360 degrees
- Output selectable within 0-20 mA, ±1 V, and ±10 V
- 85-132 V or 170-264 V AC powered
- Linearization
- Loop test output
MXS Data Sheet Product Features Applications: Position indicator using self-synch for valves and gates; Tank gauge; Sounding level meter
-
Analog Switching Module
- Switches between two analog signal channels by an external contact signal
- Switches/Distributes one voltage signal to two channels
- 100-240 V AC or 24 V DC powered
M2MNV CEUKCA Data Sheet Applications: Switching 1-5V DC signal: no contact failure that happens when using mechanical contacts for this purpose; Switching low-speed pulse signals
-
Analog Switching Module
- Selects one signal as output from up to four analog input signals
- Distributes a single input signal to any or all of the up to four output channels
- ±10 V DC input, minimum span 10mV, 50 mA max.
- 100, 110, 115, 120, 200, 220, 240 V AC or 12, 24, 48 V DC powered
MNV Data Sheet Applications: Switching 1-5 V DC signal without worrying about contact failures that happen when using mechanical contacts for this purpose; Switching low-speed pulse signals; Switching alternating signals
-
Split-Range Transmitter
- Generates four isolated signals which could control multiple final control elements
- V-shape and parallel output characteristics
- 4-20 mA input
- 85-264 V AC or 24, 110 V DC powered
MFS2 Data Sheet Product Features Applications: Balancing two final control elements in opposite actions used in heating-cooling or humidifying-dehumidifying processes
-
Split-Range Transmitter
- Generates two signals which control two final control elements
- V-shape and parallel output characteristics
- 4-20 mA input
- 12-20 mA and 4-12 mA (inverted with V-shape) outputs
- 100, 110, 115, 120, 200, 220, 240 V AC or 24 V DC powered
MFS Data Sheet Product Features Applications: Balancing two final control elements in opposite actions used in heating-cooling or humidifying-dehumidifying processes
-
Parameter Generator
- Generates a constant reference signal within the specified full-scale range
- Parameter setting is simple and easy over the entire signal range by using the front UP/DOWN switches with a help of the digital indicator.
- Specific range is ordered within 0-20 mA and ±10 V
- 100-240 V AC or 24 V DC powered
M2MST CE Data Sheet Applications: Simple solution as a simulated signal source instead of using expensive calibrators; Used also to supply a constant reference parameter for computers and DCS
-
Programmed Ramp Generator
- Generates various patterns of output by front UP-DOWN key programming
- Max. 16-point-segment ramps can be generated
- Output selectable within 0-20 mA and ±10 V.
- 100-240 V AC, 12-24 V DC, or 110 V DC powered
- Loop test output
MXMS CE Data Sheet Applications: Parameters setting for computers and DCS; Signals used in a panel, which are rarely changed.
-
16-bit Parallel Digital Output
- BCD, binary, reflected binary, two's complement outputs selectable
- Open collector or CMOS for output levels
- Output can be scaled and displayed in convenient engineering unit
- 100-240 V AC, 12-24 V DC, or 110 V DC powered
- Loop test output
- Response time adjustable within 0.15 and 60 sec.
AD3V CE Data Sheet Applications: Interface of analog signal to computers and PLC; Input to a digital panel meter
-
16-bit Parallel Digital Input
- BCD, binary, offset binary, two's complement, reflected binary inputs
- Positive or negative logic selectable
- Display can be scaled in convenient engineering unit
- 100-240 V AC, 12-24 V DC, or 110 V DC powered
DA3 CE Data Sheet Applications: Interface of analog signal for computers and PLC