Clamp-on Current Sensor CLS Series

back

Clamp-on Current Sensor CLS Series

Detecting current signals by one-touch, clamp-on connection! No need of modifying existing power lines.

  • The current sensor can be installed with no live cable modification.
  • Installation not limited inside a panel; no need of modifying existing equipment
  • Over-voltage clamp element for safety in open circuit
  • Max. 2000 A measurement
CE

Depending on the model.


CLSA Series, leadwire connection

CLSA Series, leadwire connection

  • Easy-to-install, nylon spring-loaded, clamp-on type current sensor
  • Over-voltage clamp element for safety in open circuit
  • Wide frequency band
Model Applicable
wire diameter
Operational range
CLSA-08 10 mm max. 80 A max.
CLSA-12 16 mm max. 120 A max.
CLSA-30 24 mm max. 300 A max.
CLSA-50 36 mm max. 500 A max.

CLSB Series, screw terminal connection

CLSB Series, screw terminal connection

  • Easy-to-install, spring-loaded, clamp-on type current sensor
  • Over-voltage clamp element for safety in open circuit
  • Wide frequency band
  • Screw terminal connection
Model Applicable
wire diameter
Operational range
CLSB-R5 10 mm max. 5 A max.
CLSB-05 10 mm max. 50 A max.
CLSB-10 16 mm max. 100 A max.
CLSB-20 24 mm max. 200 A max.
CLSB-40 35 mm max. 400 A max.
CLSB-60 35 mm max. 600 A max.

CLSC Series, screw terminal connection, 1 A output

CLSC Series, screw terminal connection, 1 A output

  • Easy-to-install, spring-loaded, clamp-on type current sensor
  • Over-voltage clamp element for safety in open circuit
  • 1 A output
  • Wide frequency band
  • Up to 20 kHz harmonic contents
  • Screw terminal connection
Model Applicable
wire diameter
Operational range
CLSC-10 24 mm max. 100 A max.
CLSC-25 24 mm max. 250 A max.
CLSC-50 36 mm max. 500 A max.
CLSC-60 36 mm max. 600 A max.

CLSD Series, leadwire connection, 1 A output

CLSD Series, leadwire connection, 1 A output

  • Easy-to-install, spring-loaded, clamp-on type current sensor
  • Over-voltage clamp element for safety in open circuit
  • 1 A output
Model Applicable
wire diameter
Operational range
CLSD-A 24 mm max. 150 A max. or 200 A max.
CLSD-B 36 mm max. 300 A max. or 400 A max.
CLSD-C 60 mm max. 800 A max. or 1000 A max.
CLSD-D 100 mm max. 2000 A max.

CLSE Series, screw terminal connection

CLSE Series, screw terminal connection

  • Easy-to-install, spring-loaded, clamp-on type current sensor
  • Over-voltage clamp element for safety in open circuit
  • Wide frequency band
  • Screw terminal connection
CE
Model Applicable
wire diameter
Operational range
CLSE-R5 10 mm max. 5 A max.
CLSE-05 10 mm max. 50 A max.
CLSE-10 16 mm max. 100 A max.
CLSE-20 24 mm max. 200 A max.
CLSE-40 36 mm max. 400 A max.
CLSE-60 36 mm max. 600 A max.