Clamp-on Current Sensor CLS Series
Detecting current signals by one-touch, clamp-on connection! No need of modifying existing power lines.
- The current sensor can be installed with no live cable modification.
- Installation not limited inside a panel; no need of modifying existing equipment
- Over-voltage clamp element for safety in open circuit
- Max. 2000 A measurement
Depending on the model.
CLSA Series, leadwire connection
- Easy-to-install, nylon spring-loaded, clamp-on type current sensor
- Over-voltage clamp element for safety in open circuit
- Wide frequency band
| Model | Applicable wire diameter |
Operational range |
|---|---|---|
| CLSA-08 | 10 mm max. | 80 A max. |
| CLSA-12 | 16 mm max. | 120 A max. |
| CLSA-30 | 24 mm max. | 300 A max. |
| CLSA-50 | 36 mm max. | 500 A max. |
CLSB Series, screw terminal connection
- Easy-to-install, spring-loaded, clamp-on type current sensor
- Over-voltage clamp element for safety in open circuit
- Wide frequency band
- Screw terminal connection
| Model | Applicable wire diameter |
Operational range |
|---|---|---|
| CLSB-R5 | 10 mm max. | 5 A max. |
| CLSB-05 | 10 mm max. | 50 A max. |
| CLSB-10 | 16 mm max. | 100 A max. |
| CLSB-20 | 24 mm max. | 200 A max. |
| CLSB-40 | 35 mm max. | 400 A max. |
| CLSB-60 | 35 mm max. | 600 A max. |
CLSC Series, screw terminal connection, 1 A output
- Easy-to-install, spring-loaded, clamp-on type current sensor
- Over-voltage clamp element for safety in open circuit
- 1 A output
- Wide frequency band
- Up to 20 kHz harmonic contents
- Screw terminal connection
| Model | Applicable wire diameter |
Operational range |
|---|---|---|
| CLSC-10 | 24 mm max. | 100 A max. |
| CLSC-25 | 24 mm max. | 250 A max. |
| CLSC-50 | 36 mm max. | 500 A max. |
| CLSC-60 | 36 mm max. | 600 A max. |
CLSD Series, leadwire connection, 1 A output
- Easy-to-install, spring-loaded, clamp-on type current sensor
- Over-voltage clamp element for safety in open circuit
- 1 A output
| Model | Applicable wire diameter |
Operational range |
|---|---|---|
| CLSD-A | 24 mm max. | 150 A max. or 200 A max. |
| CLSD-B | 36 mm max. | 300 A max. or 400 A max. |
| CLSD-C | 60 mm max. | 800 A max. or 1000 A max. |
| CLSD-D | 100 mm max. | 2000 A max. |
CLSE Series, screw terminal connection
- Easy-to-install, spring-loaded, clamp-on type current sensor
- Over-voltage clamp element for safety in open circuit
- Wide frequency band
- Screw terminal connection
| Model | Applicable wire diameter |
Operational range |
|---|---|---|
| CLSE-R5 | 10 mm max. | 5 A max. |
| CLSE-05 | 10 mm max. | 50 A max. |
| CLSE-10 | 16 mm max. | 100 A max. |
| CLSE-20 | 24 mm max. | 200 A max. |
| CLSE-40 | 36 mm max. | 400 A max. |
| CLSE-60 | 36 mm max. | 600 A max. |