Gateway, Remote I/O

Operating as an interface of measured signals with field networks.

The flexibility and scalability of our Remote I/O supports future system upgrades with full isolation between power-communication-I/O and between analog channels. Economical non-isolated analog modules are also selectable.

Multi-channel, Scalable Remote I/O

Compact Remote I/O

Remote I/O for FA Machinery Control

Plug-in Remote I/O

Multi Power Monitoring / Logging Unit

Compact, Scalable Remote I/O

Ultra-Slim, Scalable Remote I/O

All-in-one, Multi-point Remote I/O

Related Equipment

Wireless I/O System

  • 900 MHz Band Wireless I/O (for use in the US) WL40F Series

    900 MHz Band Wireless I/O
    (for use in the US)
    WL40F Series

  • 900 MHz Band Wireless I/O (for use in the US) R3 Series

    900 MHz Band Wireless I/O
    (for use in the US)
    R3 Series

  • Wireless Tower Light (FCC Part 15 compliant wireless module)

    Wireless Tower Light
    (FCC Part 15 compliant wireless module)
    IT40SW5F/6F
    IT50SW5F/6F
    IT60SW5F/6F

  • Wireless LAN Tower Light(for use in all EU member countries)

    Wireless LAN Tower Light
    (for use in all EU member countries)

    IT40SW1/2
    IT50SW1/2
    IT60SW1/2

    • CE
  • 920 MHz Band Wireless I/O (for use in Thailand) WL40TH Series

    920 MHz Band Wireless I/O
    (for use in Thailand)
    WL40TH Series

  • 920 MHz Band Wireless I/O (for use in Vietnam) WL40VN Series

    920 MHz Band Wireless I/O
    (for use in Vietnam)
    WL40VN Series

  • 920 MHz Band Wireless I/O (for use in Taiwan) WL40TW Series

    920 MHz Band Wireless I/O
    (for use in Taiwan)
    WL40TW Series

Other Remote I/O

Matrix Table

Specifications typical for each series are compared in the table. Details may differ depending on models.

  Plug-in
R10 Series
Slice Type, Scalable
R80 Series
Compact, Scalable
R30 Series
Slice Type, Scalable
R8 Series
 
Features
  • Main module can be easily mounted / removed thanks to the plug-in construction
  • Modbus-RTU protocol
  • High-density mounting
  • High speed, real-time Ethernet based networks
  • 12- or 24-mm wide, slim modules
  • Space-saving: no need of a backplane base
  • Suitable for Ethernet based networks
  • High internal bus speed
  • Compact 110-mm high modules allow for easy installation alongside the latest PLCs.
  • Network and power supply redundancy (under development)
  • 12- or 24-mm wide, slim modules
  • Space-saving: no need of a backplane base
  • Power/network module can be replaced without disturbing other modules.
  • I/O variations being added
Network
(*Future plan)
— — — CC-Link
— DeviceNet — DeviceNet
— PROFINET * PROFINET * —
— Modbus/TCP * Modbus/TCP Modbus/TCP
Modbus — — Modbus
— — OPC UA —
— — MECHATROLINK * —
— EtherCAT EtherCAT EtherCAT
— EtherNet/IP EtherNet/IP EtherNet/IP
— — — —
— — — —
— CC-Link IE TSN * CC-Link IE Field
CC-Link IE TSN
          —
Network redundancy — — — —
Number of I/O module types Analog input 2 models 2 models 9 models 25 models
Pulse input — — 1 model 5 models
Contact input — 2 models 1 model 13 models
Analog I/O — — — —
Contact I/O — — — —
Analog output — 2 models 2 models 11 models
Pulse output — — — 2 models
Contact output — 3 models 2 models 19 models
Analog / pulse / contact — — — 1 model
Total I/O types /
number of modules types
1 type / 2 models 7 types / 9 models 13 types / 15 models 18 types / 76 models
Power supply 24 V DC 24 V DC 24 V DC 24 V DC
Power supply redundancy — — Yes (under development) —
Dimensions
mm [inch]
W36 × H99 × D125
[1.42 × 3.90 × 4.92]
(Main module and base combined)
W128.5 × H115 × D73
[5.06 × 4.53 × 2.87]
(6 × 12-mm-wide modules)
W100 × H114 × D110
[3.94 × 4.49 × 4.33] (2 slots)
W450 × H114 × D110
[17.72 × 4.49 × 4.33] (16 slots)
W152.5 × H115 × D59
[6.00 × 4.53 × 2.32]
(8 × 12-mm-wide modules)
  Multi-channel, Scalable
R3 Series
Compact, All-in-one
R7 Series
Multi-point
R9 Series
 
Features
  • A wide range of network and I/O module with economy
  • Suitable for AC power monitoring by multi-power input, CT and PT input
  • Network and power supply redundancy
  • Network, I/O and power supply in all-in-one package
  • The smallest-size series
  • Extension discrete I/O modules are available for certain models.
  • Analog I/O can be mixed with discrete I/O in one node.
  • A wide variety of networks
  • Network, I/O and power supply in all-in-one package
  • Low-profile housing can be easily fitted into a shallow panel.
  • Calculating various AC power measurands
Network CC-Link CC-Link CC-Link
DeviceNet DeviceNet —
PROFIBUS PROFINET —
Modbus/TCP Modbus/TCP Modbus/TCP
Modbus Modbus Modbus
— — —
MECHATROLINK

MECHATROLINK-III

MECHATROLINK

MECHATROLINK-I/II, -III

—
EtherCAT EtherCAT —
EtherNet/IP EtherNet/IP —
— HLS —
FL-NetT-Link FLEX NETWORKT-Link —
CC-Link IE Field CC-Link IE Field —
Network redundancy Yes — —
Number of I/O module types Analog input 63 models 56 models 5 models
Pulse input 8 models 14 models —
Contact input 10 models 62 models —
Analog I/O — 2 models —
Contact I/O 5 models 67 models 1 model
Analog output 7 models 27 models —
Pulse output 5 models — —
Contact output 14 models 105 models —
Analog / pulse / contact 1 model — —
Total I/O types /
number of modules types
50 types / 113 models 59 types / 332 models 3 types / 6 models
Power supply 85-132 V AC, 100-120 V AC,
170-264 V AC, 200-240 V AC,
24 V DC, 110 V DC
24 V DC, 24 V AC/24 V DC
(limited availability for universal type)
100-240 V AC / 110-240 V DC
(universal type)
Power supply redundancy Yes — —
Dimensions
mm [inch]
W224 × H130 × D120 [8.82 × 5.12 × 4.72]
(8 modules)
W336 × H130 × D120 [13.23 × 5.12 × 4.72]
(12 modules)
W448 × H130 × D120 [17.64 × 5.12 × 4.72]
(16 modules)
W115 × H50 × D54 [4.53 × 1.97 × 2.13]
(R7C base module, Depend upon models. See data sheetopen in a new window.)
W125 × H140 × D80
[4.92 × 5.51 × 3.15]
(R9MWTU)
  Ultra-slim, Scalable
R6 Series
Compact, Scalable
R5 Series
Compact, Multi-point
R1 Series
 
Features
  • Ultra-slim I/O modules can be freely combined with a network module.
  • Tension-clamp, screw, euro terminal types available
  • Only 78-mm wide with 8 I/O modules (R6D or R6S)
  • A wide variety of analog input modules
  • 4-20 mA output option selectable
  • Network and power supply redundancy
  • Compact, all-in-one package
  • Low cost temperature input
  • Universal input type available
  • 1500 V AC isolation option
Network CC-Link CC-Link CC-Link
DeviceNet DeviceNet DeviceNet
PROFIBUS PROFIBUS —
Modbus/TCP Modbus/TCP —
Modbus Modbus Modbus
— — —
— — —
— — —
— — —
— — —
T-Link T-Link —
— — —
Network redundancy Yes Yes —
Number of I/O module types Analog input 18 models 38 models 6 models
Pulse input — 2 models —
Contact input 3 models 3 models 1 model
Analog I/O — — —
Contact I/O — — 1 model
Analog output 6 models 8 models —
Pulse output — 2 models —
Contact output 6 models 3 models 1 model
Analog / pulse / contact — — —
Total I/O types /
number of modules types
10 types / 33 models 22 types / 56 models 7 types / 9 models
Power supply 100-240 V AC, 24 V DC 100-120 V AC, 200-240 V AC,
24 V DC
100-240 V AC, 100 V AC,
24 V DC
Power supply redundancy — Yes —
Dimensions
mm [inch]
W78 × H99 × D116
[3.07 × 3.90 × 4.57]
(8 × tension-clamp terminal type. Depend upon terminal type. See data sheet.)
W157 × H90 × D106.5
[6.18 × 3.54 × 4.19] (4 or 5 modules)
W231 × H90 × D106.5
[9.09 × 3.54 × 4.19] (8 or 9 modules)
W379 × H90 × D106.5
[14.92 × 3.54 × 4.19] (16 modules)
W175 × H40 × D129
[6.89 × 1.57 × 5.08]
(R1MS-GH3T)