031020 | Weighing system with push-botton tare [ HTML ] [ MS Word ![]() |
031021 | Measuring the rate of material conveyed on
a conveyer belt [ HTML ] [ MS Word ![]() |
031022 | Measuring the flow output by straing gauge
transmitter [ HTML ] [ MS Word ![]() |
031023 | Zero point compensation for strain gauge transmitter [ HTML ] [ MS Word ![]() |
031024 | We use M-System's strain gauge transmitter
model MXLCF. When we re-adjust the excitation voltage to 6V, which is the
recommended value of the strain gauge, the indicator displays 20% greater
(=6 tons) than the actual load (5 tons = input 50%). [ HTML ] [ MS Word ![]() |
031025 | I have an application involving the simple
need to convert a millivolt signal from a load cell into a 4-20mA DC to
go to a PLC. Our load cell is calibrated for 2mV/V with a 10V dc excitation
supply. Which unit should I use? [ HTML ] [ MS Word ![]() |
031026 | I want to use M-System's strain gauge transmitter
model M2LCS. But there is a problem. The excitation voltage of the M2LCS
is 5V, while the recommended excitation voltage of my strain gauge is 12V. [ HTML ] [ MS Word ![]() |
![]() |
|