031080 | We are now using the potentiometer
transmitter for the potentiometer (0 -3k ohms) at site. But we are forced
to change this potentiometer (0-3k ohms) to another potentiometer (0-2k
ohms)
. [ HTML ] [ MS Word ![]() |
031081 | In ratio control, I need to change the ratio
manually at the front of the panel. [ HTML ] [ MS Word ![]() |
031082 | Automated control of inverter
frequency - applying DC/potentiometer converter [ HTML ] [ MS Word ![]() |
031083 | Do you have a remote settable potentiometer? [ HTML ] [ MS Word ![]() |
031085 | Water flow based on a level
signal in a waterway is being measured. Can I have a transmitter which provides
an output linear to the flow? The level signal is transmitted by a potentiometer
with a resistance value linear to the level. [ HTML ] [ MS Word ![]() |
031086 | I am looking for a signal conditioner which
can output either 0V or 10V DC by switching ON-OFF contact. [ HTML ] [ MS Word ![]() |
032062 | We are now using the potentiometer
transmitter; model: M2MS for the potentiometer (0 to 3k ohms) at site. But
we are forced to change this potentiometer (0 to 3k ohms) to another potentiometer
(0 to 2k ohms). [ HTML ] [ MS Word ![]() |
032079 | There is a deck gun for fire protection in
a garbage incinerator site. We are thinking to use a potentiometer for detecting
the traverse angle and elevation angle of the deck gun. We want to transfer
the angle signal to a control room at 200-meter distance from the field.
Wed like to minimize the field panel size as much as possible, hence
we think to install a potentiometer transmitter at the control room and
wire the signal from the fields potentiometer sensor to the control
room. Is this a realistic idea for us to wire the sensor for 200 meters? [ HTML ] [ MS Word ![]() |
032085 | We plan to install a damper
gear on fresh air supply duct for air volume adjustment purpose. We are going to measure the damper gate opening/shutting signal on the indicator at field end and control room end. The damper gear includes 125 ohm potentiometer as gate opening detector. We want to get 1-5 Vdc for field indication and 4-20 mAdc for control room indication. Other condition we need is small sized conditioner so that we can install it into existing small field panel. Does M-System have the conditioner fit to this application? [ HTML ] [ MS Word ![]() |
032090 | We plan to replace an
actuator at field. We are going to convert the actuators feedback
potentiometer signal to a standard 4-20 mAdc signal and then we are going
to transmit the 4-20 mA to control room for monitoring. Does M-System have field-mounted 2-wire potentiometer transmitter? With regard to a power supply for the transmitter, we are going to use the current loop supply, the M5DY. [ HTML ] [ MS Word ![]() |
![]() |
032140 | We use an inverter to control motor speed at
factory production line. A controller unit provides 4-20mA control signal and the inverter drives the motor. On the 4-20mA line, wed like to set low limit speed control adjustment manually by using potentiometer on the panel. Does M-System have any solution for this application? [ HTML ] [ MS Word ![]() |
032151 | We are looking for a simple Generator to output analog signals proportional to the set points of external contact ON signals. Do you have such a product? [ HTML ] [ MS Word ![]() |
![]() |
|