032030 | Factory drainage pH control system -- applying
analog positioner MEX [ HTML ] [ MS Word ![]() |
032032 | Cheminal feeder for Water treatment -- applying
the Mini-top model MSP [ HTML ] [ MS Word ![]() |
032033 | Pulp Concentration control system [ HTML ] [ MS Word ![]() |
032034 | Combustion control of an Industrial Gas burner
-- applying the Mini-top model MRP [ HTML ] [ MS Word ![]() |
032035 | M-System Mechatronics Series Application [ HTML ] [ MS Word ![]() |
032037 | Computer backup system -- applying analog backup
station [ HTML ] [ MS Word ![]() |
032038 | I would like to install a manual staion in the
field as backup device of a controller. And I want the manual staion to follow
its input signal (output signal from host controller) with the preset response
speed in switching manual operation to auto. [ HTML ] [ MS Word ![]() |
![]() |
032046 | Rush current [ HTML ] [ MS Word ![]() |
032060 | Self-synch transmitters [ HTML ] [ MS Word ![]() |
032061 | Application of analog backup station [ HTML ] [ MS Word ![]() |
032091 | Backup hold & manual
loading for the PID controller output failure [ HTML ] [ MS Word ![]() |
032115 | We have M-Systems Analog Backup Station
Model AB. Now we have a plan to replace an existing equipment and want to improve our flow control system. We require some additional function on this unit AB. (1) When switched from MANUAL to AUTO mode, specific fixed value is required to be output. (2) When start-up after put off the power, fixed preset valued initial output is required. We considered adding an external circuit in order to get this function. Alternatively, we can consider replacing the AB with any other M-System product, which have this kind function. Please advise. [ HTML ] [ MS Word ![]() |
032131 | We are using the synchronous transmitter (SELF-SYNCH)
to measure the opening angle of an intake gate in the river and send the
output signal of the transmitter to the synchronous receiver in a control
room to display the opening angle. As a result of monitor system standardization,
we want to convert the output signal (opening angle signal) into a standardized
signal of 4 to 20 mA in DC for instrumentation without replacing or modifying
the existing synchronous transmitter. Is there any converter suitable for
this purpose? The precise operating angle range of the synchronous transmitter
is unknown. [ HTML ] [ MS Word ![]() |
032148 | We would like to display a 4-20mA DC signal from the two-wire level transmitter. Is there a product to display the water level with alarm output, and the alarm status can be visible? [ HTML ] [ MS Word ![]() |
032152 | We like to display a water level in a tank. The 4 to 20mA DC output from a level transmitter is for 0 to 5.00 meter of water level in a oval-shaped tank. Thus, water usage and decreased water level are not proportional. Is there a digital indicator to display water usage? [ HTML ] [ MS Word ![]() |
032162 | For the production of pasta, there is a mixing process of raw materials in a tank. The raw materials can be affected by heat. To prevent it, the water temperature surrounding a tank is adjusted by controlling the valves of cold-water and heated-water. This time, we are considering a PLC to control the temperature automatically. The DeviceNet communication bus is ideal to control the valves. Is there any suitable product? [ HTML ] [ MS Word ![]() |
![]() |
|