032040 | Single point telemetering [ HTML ] [ MS Word ![]() |
032043 | Ethernet -- you still need to specify the protocol [ HTML ] [ MS Word ![]() |
032044 | Using the R1M in conjuntion
with Citect 5 -- remote I/O SCADA/HMI software package [ HTML ] [ MS Word ![]() |
032045 | R1M Application [ HTML ] [ MS Word ![]() |
032071 | We are using R1M-J3 (I/O
Module for RTD input) to monitor temperature. Is there any way to set the PC Recorder store data only when input is between a specified temperature ranges? [ HTML ] [ MS Word ![]() |
032072 | This is an application for a twin tower hotel.
There are about 100 guest rooms and the hotel wants to monitor the water
flow of each guest room. Flow meter will be used to sense the water flow,
from which voltage pulse will be generated. How can we configure a monitoring
system for the customer? [ HTML ] [ MS Word ![]() |
032073 | We have an application similar
to the one on previous issue. This one is a hotel with larger scale. They
have 800 guest rooms and want to monitor the water flow from flowmeter at
each room. Is M-System PC recorder capable in handling this? [ HTML ] [ MS Word ![]() |
032086 | We
monitor indoor temperature of clean medical safekeeping room. We put in temperature-measuring devices at several places and measure the temperature of the room. Even if one of the temperature-measuring device rise in temperature than rated value, we want to give an alarm as output. Also, we want to monitor temperature changes on PC at control room. Does M-System have suitable unit for this application. [ HTML ] [ MS Word ![]() |
032087 | PC RECORDER APPLICATIONS
Part 1 Total Pollutant Load Control for Industrial Wastewater [ HTML ] [ MS Word ![]() |
032089 | PC RECORDER APPLICATIONS
Part 2 Tap Water Supply Leakage Alarm [ HTML ] [ MS Word ![]() |
![]() |
032092 | We are trying to examine temperature
distribution in a furnace by using a PC.We plan to connect ten points
of K type T/C sensors to a recorder and measure the temperature distribution
on the PC software. Measuring temperature is around 500°C and we are
going to implant each T/C sensor in each test material and then let them
move through a conveyor in the furnace so that we can get temperature
distribution data.Do you have a suitable recorder hardware and software
for this application? |
032093 | PC RECORDER APPLICATIONS
Part 3 Power Monitoring System [ HTML ] [ MS Word ![]() |
032095 | PC RECORDER APPLICATIONS
Part 4 Monitoring at Multiple PCs via Ethernet [ HTML ] [ MS Word ![]() |
032097 | PC RECORDER APPLICATIONS Part 5 Upgrading Local Paper Recorder to Network Recording System [ HTML ] [ MS Word ![]() |
032098 | We plan to monitor the amount of power usage of each
facility in our factory. Because we set up Demand Contracts
with Electric Power Company, we do monitor the receiving power amount.
In addition, wed like to confirm the status of power use of each
facility. |
032099 | PC RECORDER APPLICATIONS Part 6 Test Data Monitoring for Solar Power Generation System [ HTML ] [ MS Word ![]() |
032101 | PC RECORDER APPLICATIONS
Part 7 Emergency Supervision for Power Facilities [ HTML ] [ MS Word ![]() |
032103 | PC RECORDER APPLICATIONS Part 8 Air Delivery System Monitoring [ HTML ] [ MS Word ![]() |
032107 | PC RECORDER APPLICATIONS
Part 9 Environmental Monitoring [ HTML ] [ MS Word ![]() |
032109 | PC RECORDER APPLICATIONS Part 10 Pulp and Paper Application [ HTML ] [ MS Word ![]() |
![]() |
032111 | PC RECORDER APPLICATIONS
Part 11 Gravure Printing Application [ HTML ] [ MS Word ![]() |
032113 | PC RECORDER APPLICATIONS Part 12 Pump Station Monitoring Using Paperless Recorder [ HTML ] [ MS Word ![]() |
032114 | At a control room, we plan
to collect field data provided by test equipment. Each test equipment is
installed in each three (3) measuring locations. There is 10-point temperature
measuring point (thermocouple) in each location. Wed like to build a PC based data acquisition system. Below listed measuring conditions are required. 1. Need to be set the data recording start/stop status via trigger input. 2. Need to be created each recorded file for each measuring point. Does M-System have any suitable device and software? [ HTML ] [ MS Word ![]() |
032117 | PC RECORDER APPLICATIONS Part 13 Water Distribution Facilities [ HTML ] [ MS Word ![]() |
032119 | PC RECORDER APPLICATIONS
Part 14 Temperature Monitoring at Food Manufacturing Plant [ HTML ] [ MS Word ![]() |
032121 | PC RECORDER APPLICATIONS Part 15 AC Current Monitoring at Hospital's Surgical Facility [ HTML ] [ MS Word ![]() |
032122 | We plan to monitor working
situation of plant equipment at control room. When field equipment has working
trouble, it will provide discrete status signal as working error and we'd
like to check it at control room. 8 discrete signals will be required to monitor at the control room. The distance between the field equipment and the field panel is approx. 50 meters. Between the field panel and the control room is approx. 200 meters. We'd like to let the warning light on at both field panel end and control room end. Does M-System have any solution with low cost? [ HTML ] [ MS Word ![]() |
032123 | PC RECORDER APPLICATIONS Part 16 Power Monitoring at a Large Shopping Mall [ HTML ] [ MS Word ![]() |
032125 | PC RECORDER APPLICATIONS Part
17 Data Acquisition from Fuel Cell Test Equipment [ HTML ] [ MS Word ![]() |
032126 | To monitor 3-phase motor’s leakage current,
we’d like to use a Zero-phase-sequence Current Transformer (ZCT) and
detect zero-phase current when earth-faulting. We want to monitor the current
by a PC. Does M-System have any suitable system/module? [ HTML ] [ MS Word ![]() |
![]() |
032127 | PC RECORDER APPLICATIONS
Part 18 Paperless recorder for the sterilizer system at food manufacturing plant [ HTML ] [ MS Word ![]() |
032130 | PC RECORDER APPLICATIONS Part 19 Temperature monitoring of continuous kiln [ HTML ] [ MS Word ![]() |
032134 | PC RECORDER APPLICATIONS
Part 20 Temperature monitoring at a synthetic fiber plant [ HTML ] [ MS Word ![]() |
032141 | We are using M-System paperless recorder, 73VR2100,
which is collecting various data of factory equipments continuously while
the factory is in operation. We shut down factory power after finishing
daily operation per each day. We are informed that the 73VR’s data
in CF card could be lost if power off the unit during data logging. Do you
have any solution? We’d like to let the 73VR stop recording before
factory power off and then start recording after factory power on every
morning. [ HTML ] [ MS Word ![]() |
032145 | We have a leased equipment at our factory.
To check the leased charge, we like to display and record the operating
time during a day by a recorder. There is ON contact signal
only available from equipment while operating. Using that signal, the operating
time needs to know by the minute. Is there a solution? [ HTML ] [ MS Word ![]() |
![]() |
|